Model: |
CP1207-10A |
|
OUTPUT |
-Output Current Range: |
10A |
|
-DC Output Voltage: |
12V±10% |
|
-Wave and Noise: |
120mVp-p |
|
-DC Output Power: |
120W |
|
-Efficiency: |
85% |
|
-DC Voltage Adjustable Scope: |
(at full load)?0.5% |
INPUT |
-Voltage Range: |
85~264VAC 47-63Hz |
|
-Input Current: |
1.1A/115V, 0.55A/230V |
|
-Leakage Current: |
<1mA/ 240VAC |
|
-Inrush Current: |
Cold start 20A/120VAC, 40A/230VAC |
PROTECTION |
-Over-Load: |
105%~135%, Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|
-Over-Voltage: |
105%—150% Rated Voltage, Protection type: Shut off |
|
-High-Temperature: |
RTH3>=65°C FAN ON<=55°C, FAN OFF>=80°C
Cut Off Output(5~15V)
|
ENVIRONMENT |
-Working Temperature: |
-10°C~+50°C |
|
-Working Humidity: |
20~90%RH |
|
-Store Temperature: |
-20°C~+85°C |
|
-Store Humidity: |
10~95%RH |
|
-Temperature Co-Efficient: |
±0.03%°C(0~50°C) |
|
-Vibration: |
10~500Hz, 2G 10min./1cycle, Period for 60min, EACH AXES |
SAFETY |
-Withstand Voltage: |
I/P-O/P: 1.5KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC |
|
-Isolation Resistance: |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
STANDARD |
-CE EMC Standard: |
EN55015:2013+A1:2015, EN61547:2009
EN61000-3-2:2014, EN61000-3-33:2013
|
|
-CE LVD Standard: |
EN61347-2-13:2014+A1:2017, EB61347-1:2015 |
|
-ROHS Standard: |
IEC 62321: 2013, EPA3050B:1996,
EN1122:2001, EPA3052:1996, EPA3060A, etc.
|
OTHER |
-Dimensions: |
199*98*43mm(L*W*H) |
|
-Weight: |